MKD, MKKD, 30MKDZ - Standard and Premium versions
MKD - double-walled insulated system used as a separate external chimney for atmospheric boilers and fireplaces. It allows the heating equipment (stove, boiler, fireplace) to be placed anywhere in the building as the chimney is led out and fixed to the wall. It comes in two versions - Premium for fuels: gas, oil, wood and pellets and Standard: designed for gas, oil, wood and pellet boilers. The system can only operate in dry conditions at temperatures up to 600 °C.
CE 0432-CPR-00095-210
EN 1856-1 T600-N1-D-V3-L50060-G50*
EN 1856-1 T600-N1-W-V2-L50060-O50*
EN 1856-1 T600-N1-D-V2-L50050-G50*
EN 1856-1 T600-N1-D-V2-L99050-G50*
EN 1856-1 T600-N1-W-V2-L99050-O50*
* G/O50 - ø80-300 mm, G/O75 - ø350-450 mm, G/O100 - ø500-600 mm
MKKD - double-walled insulated system used as a separate external chimney for boilers using the condensation of water vapour produced during combustion (so-called condensing and turbo boilers). It allows the heating appliance (boiler) to be located anywhere in the building, as the chimney is led outside and fixed to the wall. It has grooves for sealing and all the internal elements of this system are sealed. The Standard version is designed for gas and oil boilers. The system can operate in wet conditions at temperatures up to 120 °C/ 200 °C.
CE 0432-CPR-00095-215
EN 1856-1 T200-H1-W-V2-L99050-O50*
(silicone seal)
EN 1856-1 T120-H1-W-V2-L99050-O50*
(EPDM gasket)
EN 1856-1 T600-N1-D-V2-L99050-G50*
* G/O50 - ø80-300 mm, G/O75 - ø350-450 mm, G/O100 - ø500 mm
30MKDZ - double-walled insulated system used as a separate external chimney for solid fuel boilers. It allows the heating equipment to be located anywhere in the building as the chimney is led out and fixed to the wall. The Premium version is designed for the following fuels: coal, wood, pellets, eco-pea. The system can only operate in dry conditions at temperatures up to 600 °C.
CE-0432-CPR-00095-221
EN 1856-1 T600-N1-D-V3-L50080-G50*
* G/O50 - ø80-300mm, G/O75 - ø350-450mm, G/O100 - ø500-600mm
Characteristics of MKD, MKKD and 30MKDZ systems |
||||
---|---|---|---|---|
System Features | MKD Standard | MKD Premium | MKKD Standard | 30MKDZ Premium |
Gas | v | v | v | v |
Oil | v | v | v | v |
Wood | v | v | – | v |
Pellets | v | v | – | v |
Coal | – | – | – | v |
The eco-player | – | – | – | v |
Corrosion resistance | V2 | V3 | V2 | V3 |
Max. operating temperature | T600 | T600 | T120/200* | T600 |
Core material | 1.4521 | 1.4404 | 1.4521 | 1.4404 |
Thickness of core material | 0.5 mm | 0.6 mm | 0.5 mm | 0.8 mm |
Insulation | mineral wool | mineral wool | mineral wool | mineral wool |
Insulation thickness | 30 mm | 30 mm | 30 mm | 30 mm |
Type of operation | vacuum | vacuum | overpressure | vacuum |
Resistance to soot fire | v | v | v | v |
Attestations / Certificates | CE 0432-CPR-00095-210 | CE 0432-CPR-00095-210 | CE 0432-CPR-00095-215 | CE-0432-CPR-00095-221 |
Warranty | 30 years | 30 years | 30 years | 5 years |
Seal warranty | – | – | 2 years | – |